Shrnutí obsahu

Strany 1 - Card Issuance Systems

Datacard® Maxsys® and MX Series Card Issuance SystemsAdministrator’s GuideSoftware Version 5.6 SP2 July 2011Part No. 539523-006, Rev B

Strany 2 - Trademark Acknowledgments

x Microsoft Windows Updates__________________________________________________ 221Managing the Password for the Datacard System Default User Name ____

Strany 3

88 Card Setup4. In this example, two text element with the same data are placed on the card. The top text element is using Tabgroup1 and the other do

Strany 4

Maxsys and MX Series Software Administrator’s Guide 89 you should verify that the emboss data (the source operation) is contained in the magnetic stri

Strany 5 - Contents

90 Card Setuptype of problem. If there is a machine Controller software problem, it should be investigated by Datacard customer support.

Strany 6

Maxsys and MX Series Software Administrator’s Guide 91 To override the default exposure value, select the Override check box and then enter a numeric

Strany 7

92 Card SetupMagnetic Stripe Verify ElementUse the following information to define properties of a Magnetic Stripe Verify Element.Trailing Encode Fil

Strany 8

Maxsys and MX Series Software Administrator’s Guide 93 Magnetic Stripe Read ElementUse the following information to define the properties of a Magneti

Strany 9

94 Card SetupContact Smart Card ElementUse the following information to define the properties of a Contact Smart Card Element.Settings Tab Properties

Strany 10

Maxsys and MX Series Software Administrator’s Guide 95 Contactless Smart Card ElementUse the following information to define the properties of a Conta

Strany 11

96 Card SetupApplication Select a Smart Card application to use for this operation.Use Custom Module CapabilityAllows you to split contactless module

Strany 12 - Revision Log

Maxsys and MX Series Software Administrator’s Guide 97 Combi Smart Card ElementUse the following information to define the properties of a Combi Smart

Strany 13 - Software

xi Bitmap Image Element __________________________________________________ 276Bitmap Text Element ___________________________________________________

Strany 14

98 Card SetupUsed Select the check box to use.DestinationFeedback FieldsThe fields into which the value generated by the source fields are copiedCryp

Strany 15 - Production

Maxsys and MX Series Software Administrator’s Guide 99 RFID Write ElementUse the following information to define the properties of an RFID Write Eleme

Strany 16 - Production Station Interface

100 Card SetupScanner ElementUse the following information to define the properties of a Scanner Element.Settings Tab PropertiesName The name of the

Strany 17 - Lower Status Bar

Maxsys and MX Series Software Administrator’s Guide 101 Image ElementUse the following information to define the properties of an Image Element.Settin

Strany 18

102 Card SetupAdvanced Tab PropertiesForeground Opacity Use the slider to set the opacity valueBackground OpacitySelect Opaque or TransparentRotation

Strany 19 - Ready Jobs Tab

Maxsys and MX Series Software Administrator’s Guide 103 Text ElementUse the following information

Strany 20

104 Card SetupSide The side of the card (Front or Back) on which the operation is to occurX/Y The horizontal and vertical coordinates (measured from

Strany 21 - Production Tab

Maxsys and MX Series Software Administrator’s Guide 105 Print Process The process used in the printing operation. This selection should correspond to

Strany 22 - 10 About the Software

106 Card SetupBarcode ElementUse the following information to define the properties of a Barcode Element.Element Group Element Groups allow you to sp

Strany 23 - Roll-Over Functionality

Maxsys and MX Series Software Administrator’s Guide 107 Z-Order Sets the front to back order of elements on the Z axis. Zero (0) represents the farthe

Strany 24 - All Jobs Tab

xii Revision LogMaxsys and MX Series Card Issuance Systems Administrator’s GuideRevision Date Description of ChangesA April 2011 First release of this

Strany 25 - Syntera Interface

108 Card Setup Scale Select the check box, and

Strany 26 - Filtering Tool

Maxsys and MX Series Software Administrator’s Guide 109 UltraGrafix Language ElementUse the following information to define the properties of an Ultra

Strany 27 - Job Details Tab

110 Card SetupTopcoat/Laminate ElementUse the following information to define the properties of a Topcoat/Laminate Element.Element Group Element Grou

Strany 28 - Job List Pane

Maxsys and MX Series Software Administrator’s Guide 111 Emboss Element PropertiesUse the following information to define the properties of an Emboss E

Strany 29 - Filter Tool

112 Card SetupY The vertical coordinate at which the operation is to occur. Click the icon to use Data Field information for the Y coordinate.• For M

Strany 30 - Job Grouping by Input File

Maxsys and MX Series Software Administrator’s Guide 113 Indent ElementUse the following information to define the properties of an Indent Element.Inde

Strany 31 - Production Preferences

114 Card SetupX The horizontal coordinate at which the operation is to occur. Click the icon to use Data Field information for the X coordinate.• For

Strany 32 - General Tab

Maxsys and MX Series Software Administrator’s Guide 115 Direction Forward or Reverse, the direction on the card the indent printing is to occurSeconda

Strany 33 - Tables Tab

116 Card SetupTopping ElementUse the following information to define the properties of a Topping Element.Settings Tab PropertiesName The name of the

Strany 34 - FIR Record Tab

Maxsys and MX Series Software Administrator’s Guide 117 Laser Engraving ElementUse the following information to define the properties of a Laser Engra

Strany 35 - Event Log

Maxsys and MX Series Software Administrator’s Guide 1Chapter 1: About the SoftwareThis chapter provides an overview of the Datacard® Maxsys®, and MX S

Strany 36 - Utilities

118 Card SetupLabel ElementUse the following information to define the properties of a Label Element.Settings Tab PropertiesName The name of the Labe

Strany 37 - Vision Utilities

Maxsys and MX Series Software Administrator’s Guide 119 Sticker ElementUse the following information to define the properties of a Sticker Element.Dyn

Strany 38 - Security

120 Card SetupX (Ref)/Y (Ref) The reference coordinates (in inches) for the dynamic OCV element. Click the icon to select Data Field information for

Strany 39 - Chapter 2: Production

Maxsys and MX Series Software Administrator’s Guide 121 Running Mini-CardsCard Setup changes are necessary to run the ID-K specified mini-card (refer

Strany 40 - Loading Jobs

122 Card SetupUsing MasterCard Titanium CardsMasterCard® Titanium cards have a different shape from typical credit cards.

Strany 41 - Loading Syntera Jobs

Maxsys and MX Series Software Administrator’s Guide 123 C. On the Settings tab of the Card Properties window define the parameters as needed (consult

Strany 42 - 30 Production

124 Card Setupnarrower the scope of the search. The following table describes the search parameters.• Click Search. Any jobs fitting the search crite

Strany 43

Maxsys and MX Series Software Administrator’s Guide 125 selection. Select the Product Record option button to preview the card using data from a loade

Strany 44 - 32 Production

126 Card SetupAfter establishing the data source, click OK to return to the previous tab on which you were working.

Strany 45 - Using the Standard Method

Maxsys and MX Series Software Administrator’s Guide 127 Unicode Font Image Generation ErrorsIf a font has been created with non-standard unicode conte

Strany 46 - 34 Production

2 About the SoftwareSetups The Setups menu contains the following setups:• Job Setup• Data Setup• Card Setup• Form Setup• Production Options Setup• A

Strany 47 - Using QuickConnect

128 Card SetupPrinting Card SetupsTo print a screen capture of a Card Setup window, complete the following steps.1. From the Card Setup window (Appli

Strany 48 - Running Jobs

Maxsys and MX Series Software Administrator’s Guide 129Chapter 7: Form SetupThis chapter provides information on creating and modifying Form Setups.Cr

Strany 49

130 Form Setup3. In the Form Properties pane, select a Data Setup by clicking Browse and then navigating to a Data Setup. Select the setup and then c

Strany 50 - Viewing Jobs

Maxsys and MX Series Software Administrator’s Guide 131 5. Select the Show Sample Data check box if you would like sample data displayed on the form.

Strany 51 - Viewing Cards/Forms

132 Form Setup When the fold type is not a data field, the checkbox for using default fold locatio

Strany 52 - 40 Production

Maxsys and MX Series Software Administrator’s Guide 133 The Virtual FormThe virtual form in the Form Setup application allows you to manually select t

Strany 53 - • Click OK when finished

134 Form SetupPositioning the FoldsWith your mouse, left-click on the fold (or folds, based on the fold type selected) and hold down to position it v

Strany 54 - Remaking Jobs

Maxsys and MX Series Software Administrator’s Guide 135 2. Right-click on the card to di

Strany 55 - Splitting Jobs

136 Form Setup Aligning the Barcode1. Select, hold, and drag the Barcode to position it

Strany 56 - Advanced Splitting

Maxsys and MX Series Software Administrator’s Guide 137 Alternately, you can click on th

Strany 57 - Splitting Syntera Jobs

Maxsys and MX Series Software Administrator’s Guide 3 Diagnostics are generally not documented in

Strany 58 - Searching for Jobs

138 Form SetupMapping Merge FieldsMapping merge fields allows you to map fields from the template, card feedback fields, and runtime composites to a

Strany 59

Maxsys and MX Series Software Administrator’s Guide 139 Configuring the MXi Envelope InserterSet up jobs for the envelope inserter option on your MXi

Strany 60 - Deleting Jobs

140 Form Setup 3. Select the hopper from which the insert will be taken.Module 0 is used

Strany 61

Maxsys and MX Series Software Administrator’s Guide 141 4. Select the Item Id. Assign an

Strany 62 - 50 Production

142 Form SetupConfiguring MXi in Form SetupPerform the following procedure to configure the MXi job(s) in the Maxsys/MX Series Form Setup.When the MX

Strany 63 - Adding Station Notes

Maxsys and MX Series Software Administrator’s Guide 143 For example, the image below shows two lines of selective insert data. The tags ip1, ip2, and

Strany 65 - Chapter 3: The Event Log

Maxsys and MX Series Software Administrator’s Guide 145Chapter 8: ProductionOptions SetupThis chapter provides information on creating and modifying P

Strany 66 - 54 The Event Log

146 Production Options SetupSettings TabAuto Remake Mode:• Off—The system will not attempt auto remakes.• Preserve Data Order—Entire Machine—The syst

Strany 67

Maxsys and MX Series Software Administrator’s Guide 147 • Reusable Reject Station—Select if you have a reusable reject station set up in Diagnostics.•

Strany 68

4 About the SoftwareProduction Station InterfaceThe components of the Production interface include upper and lower status bars and tabs that display

Strany 69 - Event Viewing Options

148 Production Options SetupAllow Double Topping - With this option selected, the card is topped twice (if needed) by the same Topping Module. The ca

Strany 70 - Sorting Returned Events

Maxsys and MX Series Software Administrator’s Guide 149 Emboss Groups Tab (Maxsys Only)T

Strany 71 - Exporting Events

150 Production Options Setupcombined with the selection of emboss group number in Card Setup which will modify system behavior.In the example above,

Strany 72 - Purging the Event Log

Maxsys and MX Series Software Administrator’s Guide 151 control. A sample Card Setup screen shot is shown below. In this scenario, emboss operation “a

Strany 73 - Chapter 4: Job Setup

152 Production Options Setup

Strany 74 - The Settings Tab

Maxsys and MX Series Software Administrator’s Guide 153Chapter 9: Audit SetupThis chapter provides information on creating and modifying Audit Setups.

Strany 75 - The Selection Criteria Tab

154 Audit Setup• In the Report Type list, indicate whether the existing audit report has character separated fields or fixed length fields.• If this

Strany 76 - 64 Job Setup

Maxsys and MX Series Software Administrator’s Guide 155 • To adjust the order in which the fields will appear in the audit report, select the fields a

Strany 77 - Chapter 5: Data Setup

156 Audit Setup• If necessary, select Add Machine ID to File Path. This will automatically add the machine ID to the file name. You can see the outpu

Strany 78 - Defining Data Input Files

Maxsys and MX Series Software Administrator’s Guide 157Chapter 10: Global SetupsThis chapter contains information on creating and modifying global set

Strany 79 - Adding Fields

Maxsys and MX Series Software Administrator’s Guide 5 Lower Status BarThe lower status bar has program tabs on the left side that display all open app

Strany 80 - Adding Data Fields

158 Global SetupsPlacementQuiet Zone Whitespace before and after the barcode. Select the checkbox to enable.Bearer Bars A bar across the top and bott

Strany 81

Maxsys and MX6000 Software Administrator’s Guide 159 3. Click Save (if you are modifying an existing setup to define as a new setup click Save As). 4.

Strany 82 - Adding Constant Fields

160 Global SetupsEmboss Font SetupAdding Emboss Font or Indent Font DefinitionsEmboss/Indent font definitions are used in Emboss/Indent operations an

Strany 83 - Adding FIR Fields

Maxsys and MX6000 Software Administrator’s Guide 161 Emboss Mapping SetupEmboss Mapping Setups allow you to map any character of any font to be used a

Strany 84 - Adding Composite Fields

162 Global SetupsMagstripe SetupCreating a New Magstripe SetupMagstripe Setup allows you to define the behavior of a magnetic stripe encoding process

Strany 85

Maxsys and MX6000 Software Administrator’s Guide 163 Defining the Magnetic Stripe PropertiesDefine the magnetic stripe properties as detailed in the f

Strany 86

164 Global SetupsTrack Map EntriesMagnetic Stripe Setup allows you the option of altering the input character/bit pattern combination to customize yo

Strany 87

Maxsys and MX6000 Software Administrator’s Guide 165 Image Placement SetupPositioning an Image FileThe Image Placement Setup application is used to po

Strany 88 - Adding Display Fields

166 Global SetupsCreating a New Image Placement SetupComplete the following steps to create a new Image Placement Setup.1. Select Applications | Glob

Strany 89

Maxsys and MX6000 Software Administrator’s Guide 167 the camera setup allows the same camera setup to be used across modules (of the same type) and sy

Strany 90 - Deleting Data Setups

6 About the SoftwareSyntera-Integrated Upper Status Bar If the Production application is

Strany 91 - Chapter 6: Card Setup

168 Global Setups6. To use a character set that is different from the default (A-Z and 0-9), deselect Use Default Character Set and then enter the de

Strany 92 - Creating a New Card Setup

Maxsys and MX Series Software Administrator’s Guide 169Chapter 11: StocksThis chapter provides information on creating and modifying your stock invent

Strany 93

170 StocksMaxsys 3.1 system to a Maxsys 3.1 and above system. However, it is not acceptable to copy Maxsys 3.1+ stock files to a pre-Maxsys 3.1 syste

Strany 94

Maxsys and MX Series Software Administrator’s Guide 171 2. From the Stock Types list, se

Strany 95 - Defining Card Properties

172 Stocks4. Complete the stock description by filling out the fields provided (see the next section for details).The name you enter in the Stock Nam

Strany 96 - 84 Card Setup

Maxsys and MX Series Software Administrator’s Guide 173 Form StockIndent Ribbon StockLabel StockParameter DescriptionStock Name Unique, descriptive na

Strany 97 - The Advanced Tab

174 StocksMonochrome Ribbon StockPassport Stock and Passport Laminate Stock appear in the list for Maxsys and MX Series systems; however, it is not a

Strany 98 - Manage Tab Groups

Maxsys and MX Series Software Administrator’s Guide 175 Retransfer Stock Set1. Select a process type and then click Add to create a new Print Process

Strany 99

176 StocksRetransfer Stock Set CMYK_GoldRibbon Stocks TabParameter DescriptionStock Name Unique, descriptive name of the stockDescription A descripti

Strany 100 - The Crosscheck Tab

Maxsys and MX Series Software Administrator’s Guide 177 Roller StockTopcoat/Laminate StockTopping Foil StockEditing Stock DescriptionsComplete the fol

Strany 101 - Operations Tab

Maxsys and MX Series Software Administrator’s Guide 7 Syntera Toolbar Shortcut IconsThe Syntera interface also contains a group of icons under the upp

Strany 102 - Vision Verification Tab

178 Stocks2. Select the stock item to change and click Open. The stock definition dialog window for the selected stock opens.3. Change the informatio

Strany 103 - Defining Element Properties

Maxsys and MX Series Software Administrator’s Guide 179 3. Drag the Pattern Match/Optical Character Verification (OCV) elements to the virtual card.4.

Strany 104 - Element

180 StocksCard Stock ElementsThere are two types of elements that can be placed on the Card Stock, Pattern Match and Optical Character Verification (

Strany 105 - Magnetic Stripe Read Element

Maxsys and MX Series Software Administrator’s Guide 181 Y Vertical offset (in inches) from the bottom-let corner of the cardWidth Width (in inches) of

Strany 106 - Contact Smart Card Element

182 StocksOptical Character Verification (OCV)Settings TabParameter DescriptionName Descriptive Name (OCV1 by default)Side The side of the card (Fron

Strany 107 - Card Element

Maxsys and MX Series Software Administrator’s Guide 183 Advanced TabTesting Card Stock ElementsOnce the Pattern Match/OCV elements are placed on the c

Strany 108

184 Stocks • In the second example, the test passed but only with an average score of 47

Strany 109 - Combi Smart Card Element

Maxsys and MX Series Software Administrator’s Guide 185Chapter 12: Smart Card ManagementThis chapter provides information on using the Smart Card Mana

Strany 110

186 Smart Card Managementand then use Key Reader Management to define the key readers and to assign key cards to key readers.Crypto Device Management

Strany 111 - RFID Read Element

Maxsys and MX Series Software Administrator’s Guide 187 3. For name, enter a name for th

Strany 112 - Scanner Element

iiLiability StatementPlease do not attempt to operate or repair this equipment without adequate training. Any use, operation, or repair in contravent

Strany 113 - Image Element

8 About the Softwareinformation on displaying jobs, refer to "Choose Columns to Be Displayed" on page 17 and “Job Grouping by Input File” o

Strany 114

188 Smart Card Management12. Once you have a value in the Check Value field, click the Get Alias button. This should highlight one of the values in

Strany 115 - Text Element

Maxsys and MX Series Software Administrator’s Guide 189 Key Card ManagementKey Card Management enables the user to create key card groups, add key ca

Strany 116

190 Smart Card ManagementAdding Key CardsEach key card assigned to a group must be identical to the other key cards in that group. To add a key card

Strany 117

Maxsys and MX Series Software Administrator’s Guide 191 Deleting Key Card GroupsTo delete a key card group, complete the following steps.1. Select App

Strany 118 - Barcode Element

192 Smart Card ManagementModifying Key Card GroupsTo modify a key card group, complete the following steps. 1. Select Applications | Smart Card Manag

Strany 119

Maxsys and MX Series Software Administrator’s Guide 193 Modifying Key CardsTo modify a key card, complete the following steps.1. Select Applications |

Strany 120

194 Smart Card ManagementKey Reader ManagementKey readers read key cards that are required to encrypt and decrypt data sent to smart cards during the

Strany 121 - UltraGrafix Language Element

Maxsys and MX Series Software Administrator’s Guide 195 3. Enter a name for the key reader in the Name text box.4. Enter a description of the key read

Strany 122 - Topcoat/Laminate Element

196 Smart Card ManagementDeleting a Key ReaderTo delete a key reader, complete the following steps.1. Select Applications | Smart Card Management | K

Strany 123 - Emboss Element Properties

Maxsys and MX Series Software Administrator’s Guide 197 Testing a Key ReaderWhen testing Datacard key readers, the test function checks for a TCP/IP c

Strany 124

Maxsys and MX Series Software Administrator’s Guide 9 Production TabThe Production tab provides a visual representation of the entire system and syste

Strany 125 - Indent Element

198 Smart Card Management3. For Check Value, enter the check value of the LMK. Typical values are 16 characters in length. This value can be copied f

Strany 126

Maxsys and MX Series Software Administrator’s Guide 199Chapter 13: Hex DumpThis chapter provides information about using the Hex Dump tool.Using the H

Strany 127

200 Hex DumpPerform the following steps to use the Hex Dump tool:1. Select Application | Utilities | Hex Dump.2. Select a Data File to view by clicki

Strany 128 - Topping Element

Maxsys and MX6000 Software Administrator’s Guide 201 FindPerform the following steps to use the Find command in Hex Dump tool:1. To search the data us

Strany 129 - Laser Engraving Element

202 Hex DumpGo To OffsetPerform the following steps to use the Hex Dump Go To Offset tool:1. To search the data using the Go To Offset tool select Ed

Strany 130 - Label Element

Maxsys and MX Series Software Administrator’s Guide 203Chapter 14: SecurityConfigurationThis chapter contains information on the use of the Security C

Strany 131 - Dynamic OCV Element

204 Security Configuration• Users needing to extract a trace through the Diagnostics application must have permission to access the Maxsys DB2 databa

Strany 132

Maxsys and MX6000 Software Administrator’s Guide 205 • Select multiple domains by using Ctrl/Shift+Click.All available domain groups appear in the Ava

Strany 133 - Running Mini-Cards

206 Security Configuration 3. If necessary, choose the location in which to save the sec

Strany 134 - 122 Card Setup

Maxsys and MX Series Software Administrator’s Guide 207Chapter 15: Export SetupsThis chapter contains information on the use of the Export Setups util

Strany 135

10 About the Software A Visual Representation of the SystemEach module in the system is

Strany 136

208 Export Setups2. Click a button in the Select Files to Export pane. In this example, a Job Setup is selected and the Choose dialog opens and the J

Strany 137

Maxsys and MX Series Software Administrator’s Guide 209 3. Select the files to export (for multiple files hold the Ctrl key and select the files) and

Strany 138

210 Export Setups5. Click Save from the toolbar.6. Browse to a location to save the zip file. Click Choose.7. When the export if finished, optionally

Strany 139

Maxsys and MX Series Software Administrator’s Guide 211Chapter 16: Keyboard EntryThis chapter contains information on the use of the Keyboard Entry ut

Strany 140 - Printing Card Setups

212 Keyboard EntryUsing Keyboard EntryPerform the following steps to use this utility:1. Select Applications | Utilities | Keyboard Entry from the me

Strany 141 - Chapter 7: Form Setup

Maxsys and MX Series Software Administrator’s Guide 213 • To enter string or binary FIR information manually using the FIR Fields box, select FIR Fiel

Strany 142 - 130 Form Setup

214 Keyboard Entry• Browse - References files for field data types that are not easily added using the keyboard or Cut and Paste. For example: Binary

Strany 143

Maxsys and MX Series Software Administrator’s Guide 215Chapter 17: Back Up and RestoreThis chapter contains information on backing up and restoring a

Strany 144 - 132 Form Setup

216 Back Up and Restore7. At the Confirmation dialog verify that only tables with a schema of Maxsys are displayed.8. Select OK.9. Restart Datacard M

Strany 145 - The Virtual Form

Maxsys and MX Series Software Administrator’s Guide 217 Once the backup is completed, remove the Acronis boot CD from the CD drive, close the Acronis

Strany 146 - Placing and Aligning Cards

Maxsys and MX Series Software Administrator’s Guide 11 • Red indicates that an error condition exists. A corresponding error message appears in the me

Strany 147

218 Back Up and Restore12. No change is needed for Restoration Options, so click Next.13. For login information, just click Next.14. Confirm every

Strany 148 - Aligning the Barcode

Maxsys and MX Series Software Administrator’s Guide 219Appendix A: MiscellaneousConfigurationThis appendix covers various administrative issues that m

Strany 149

220 Miscellaneous Configuration If the password is changed for any reason, (either Local or Domain

Strany 150 - Mapping Merge Fields

Maxsys and MX Series Software Administrator’s Guide 221 Anti-VirusDatacard does not validate, endorse, or recommend the use of a specific anti-virus s

Strany 151

222 Miscellaneous ConfigurationManaging the Password for the Datacard System Default User NameDatacard Maxsys, MX Series, and PB6500 systems are ship

Strany 152 - 140 Form Setup

Maxsys and MX Series Software Administrator’s Guide 223

Strany 153

224 Miscellaneous ConfigurationFont Mapping/Datacard Converted Fonts This feature was developed for customers who call out fonts in their data on a D

Strany 154 - Configuring MXi in Form Setup

Maxsys and MX Series Software Administrator’s Guide 225 4. The following fonts are pre-defined; however, if the system detects the presence of the dcc

Strany 155

226 Miscellaneous ConfigurationPossible ErrorsThe following errors may be generated. Check the structure of your code to prevent such errors from occ

Strany 156 - 144 Form Setup

Maxsys and MX Series Software Administrator’s Guide 227Appendix B: VisionVerification ModuleThis appendix provides information about using the Vision

Strany 157 - Options Setup

12 About the SoftwareAll Jobs TabThe All Jobs tab displays the Production All Jobs screen, which contains a list of all loaded jobs, of any status. D

Strany 158 - Settings Tab

228 Vision Verification Module As shown in the illustration above, when a card enters th

Strany 159

Maxsys and MX Series Software Administrator’s Guide 229 Fi fAs mentioned, the Vision Ver

Strany 160 - Station Groups Tab

230 Vision Verification Module4. From the Batch Size list, select the number that corresponds to the number of cards you will load in the Card Input

Strany 161

Maxsys and MX Series Software Administrator’s Guide 231 Pattern Match Element9. Select t

Strany 162 - 150 Production Options Setup

232 Vision Verification Module To cr

Strany 163

Maxsys and MX Series Software Administrator’s Guide 233 Optical Character Verification E

Strany 164 - 152 Production Options Setup

234 Vision Verification Module 10. Use the mouse to crop the box around the text.The bo

Strany 165 - Chapter 9: Audit Setup

Maxsys and MX Series Software Administrator’s Guide 235 16. Enter a Pass Threshold value that is as high as you can without causing too many false re

Strany 166 - 154 Audit Setup

236 Vision Verification ModuleWhether you use a graphic element or a text element for verification, you will need to specify verification details in

Strany 167

Maxsys and MX Series Software Administrator’s Guide 237 Card Stock with a Card Setup that has a Dynamic OCV Element This procedure can be performed at

Strany 168 - 156 Audit Setup

Maxsys and MX Series Software Administrator’s Guide 13 Syntera InterfaceOn the Syntera-integrated Production interface, the All Jobs tab provides the

Strany 169 - Chapter 10: Global Setups

238 Vision Verification Module7. Move the crosshair so that the horizontal line of the crosshair is on the baseline of the text and the vertical line

Strany 170

Maxsys and MX Series Software Administrator’s Guide 239 Vision RegistrationSome card stocks are designed with tight tolerances for areas that are mean

Strany 171

240 Vision Verification Module2. On the toolbar click Open and then, from the Open dialog box, select the Card Setup to work with.3. Select the card

Strany 172 - Emboss Font Setup

Maxsys and MX Series Software Administrator’s Guide 241 5. Click Save.When the Card Setup is used to produce cards, the elements you selected for qual

Strany 173 - Emboss Mapping Setup

242 Vision Verification ModuleFont Creation Procedure1. Determine which characters are required to perform the verification or OCV operation. The cre

Strany 174 - Magstripe Setup

Maxsys and MX Series Software Administrator’s Guide 243Appendix C: Artista VHD ModuleThis appendix explains how to create the setups necessary for pri

Strany 175

244 Artista VHD Module6. For Retransfer Material, select AVHD_RTM.7. For Primer, select AVHD_PRIMER. At this point your Ribbon Stock Setup will look

Strany 176 - Track Map Entries

Maxsys and MX Series Software Administrator’s Guide 245 15. Enter “black” for the Print Process. (This Print Process will be used for black text on t

Strany 177 - Image Placement Setup

246 Artista VHD ModuleThe example card requires three graphics files: brothers.jpglogo.

Strany 178 - Camera Setup

Maxsys and MX Series Software Administrator’s Guide 247 A. From the element list, drag an Image Element to the Front Side of the card.B. In the Settin

Strany 179 - OCR Font Setup

14 About the SoftwareFiltering ToolThe All Jobs tab also includes a filtering tool for quickly locating jobs based on their parameters. Use the filte

Strany 180 - Character Set text box

248 Artista VHD Module6. To specify static text to appear on each card, follow these steps:A. From the element list, drag a Text Element to the Front

Strany 181 - Chapter 11: Stocks

Maxsys and MX Series Software Administrator’s Guide 249Appendix D: Resource Editor Translation ToolThis appendix contains information about using the

Strany 182 - Units of Measure

250 Resource Editor Translation ToolTo use the Resource Editor tool, follow these steps:When viewing a translation in the Resource Editor, the follow

Strany 183 - Adding Stock Descriptions

Maxsys and MX Series Software Administrator’s Guide 251 8. To view multiple columns, cli

Strany 184 - Stock Descriptions by Type

252 Resource Editor Translation Tool10. To add a new translation:A. Select the file tab for which you want to add a translation.B. From the Tools me

Strany 185 - Label Stock

Maxsys and MX Series Software Administrator’s Guide 253 11. To view the difference between the default resource bundles and determine any properties

Strany 186 - Retransfer Stock

254 Resource Editor Translation Tool12. To merge translations:A. From the Tools menu, select Merge Translations. The Merge tab opens.B. Browse to th

Strany 187 - Retransfer Stock Set

Maxsys and MX Series Software Administrator’s Guide 255 Tip SheetThe Resource Editor tip sheet provides information on the use of the tool. This docum

Strany 188

256 Resource Editor Translation Tool

Strany 189 - Editing Stock Descriptions

Maxsys and MX Series Software Administrator’s Guide 257Appendix E: ConCADThis chapter contains information on the setup and use of the ConCAD utility.

Strany 190 - Card Stock Setups

Maxsys and MX Series Software Administrator’s Guide 15 Job Details TabThe Job Details tab in the Production area provides information to monitor (in r

Strany 191 - Defining Card Stocks

258 ConCADLayout PropertiesUse Layout Properties to define the features of the layout. To access right-click in the page area where there is no eleme

Strany 192 - Card Stock Elements

Maxsys and MX Series Software Administrator’s Guide 259 Background ImageThe background image gives a visual representation of preprinted artwork, it i

Strany 193 - Image Name The image name

260 ConCADProfilesUse the profiles tab to define the Vision, Camera and Laser Profiles for a layout.

Strany 194

Maxsys and MX Series Software Administrator’s Guide 261 Camera ProfilesCamera profiles are used for vision verification operations. Camera profiles de

Strany 195 - Testing Card Stock Elements

262 ConCADGrid GuidelinesGrid x/y distances (the distance between grid lines), grid color, and guideline color are defined on this tab. The grid can

Strany 196 - 184 Stocks

Maxsys and MX Series Software Administrator’s Guide 263 MenusFile Tool DescriptionNewNew Laser Temp

Strany 197 - Management

264 ConCADEditFollowing are the operations available from the edit menu. To select multiple objects press and hold CTRL and click on the objects. Ele

Strany 198 - Crypto Device Management

Maxsys and MX Series Software Administrator’s Guide 265 Service for assistance if ther is a need a specially developed or modified vector font.ViewThe

Strany 199

266 ConCADThe ToolbarThe toolbar groups in the ConCAD program are listed below.

Strany 200 - Testing Crypto Devices

Maxsys and MX Series Software Administrator’s Guide 267 ButtonsThe following buttons appear in most dialogs.The Element Property WindowThe Element pro

Strany 201 - Key Card Management

16 About the SoftwarePrint PreviewSelect one or more records displayed in the Job Details tab and select Print Preview option to preview the selected

Strany 202 - Adding Key Cards

268 ConCADProcessing TabThis tab is common to all elements in a laser template.•Horizontal axis• Vertical axis(MX6000)• No Tilting (default) - If “No

Strany 203 - Deleting Key Cards

Maxsys and MX Series Software Administrator’s Guide 269 Bitmap Settings TabThis tab is common to all bitmapped elements.Alignment Point The x/y coordi

Strany 204 - Modifying Key Card Groups

270 ConCADBMP Laser DetailsUse this tab to set laser details for bitmapped elements. The Raster Mode, Line direction, Color Mode, Scan Mode and other

Strany 205 - Modifying Key Cards

Maxsys and MX Series Software Administrator’s Guide 271 Mode 3 (x/y half shifted, 45°) Mode 5 (Inde

Strany 206 - Key Reader Management

272 ConCADVerification TabUse this tab to enable Verification functionality and set the threshold value. Select the Verify Element Quality check box

Strany 207

Maxsys and MX Series Software Administrator’s Guide 273 4. Set the data contrast.5. Optionally select ICAO Specification6. Optionally perform the conf

Strany 208 - Resetting a Key Reader

274 ConCADInput Levels - Adjust the Black and White Threshold levels to attain the best looking image. Increasing the black level will result in a da

Strany 209 - Testing a Key Reader

Maxsys and MX Series Software Administrator’s Guide 275 Auto Levels - ConCAD identifies the lightest and darkest pixels and then redistributes interme

Strany 210 - 198 Smart Card Management

276 ConCADBitmap Image ElementFile The path to the image file. If necessary, click the ellipses (...) button to navigate to a different image.Embedde

Strany 211 - Chapter 13: Hex Dump

Maxsys and MX Series Software Administrator’s Guide 277 Bitmap Text ElementUse this tab to define text and font settings.Resize Algorithm ConCAD suppo

Strany 212 - 200 Hex Dump

Maxsys and MX Series Software Administrator’s Guide 17 Filter ToolIf the selected job contains a large number of cards, use the filter tool to limit t

Strany 213

278 ConCADFont Attributes Select any combination of the following font attributes: Bold, Italic, Underline, Strikeout, Smoothing. Smoothing font edge

Strany 214 - Go To Offset

Maxsys and MX Series Software Administrator’s Guide 279 Solid Box ElementUse this tab to define a solid box filled with a shade of gray.Wedge ElementW

Strany 215 - Configuration

280 ConCADVector Settings TabVector elements are available for laser templates only. The vector settings tab is common to all vector-based images.Vec

Strany 216 - Using Security Configuration

Maxsys and MX Series Software Administrator’s Guide 281 Vector Line ElementThis tab allows you to define x/y-coordinates for the line's start and

Strany 217

282 ConCADVector Circle ElementVector Ellipse ElementCenter Point Location of the circle’s center point.Radius The size of the circle (in mm).Start A

Strany 218 - 206 Security Configuration

Maxsys and MX Series Software Administrator’s Guide 283 Vector Beziér Spline ElementUse this tab to define coordinates for all four points of the spli

Strany 219 - Chapter 15: Export Setups

284 ConCADVectorized (TTF) Text ElementThis element is available for laser templates.Text The text string to be lased.Font The font that will be used

Strany 220 - 208 Export Setups

Maxsys and MX Series Software Administrator’s Guide 285 Perforated Number ElementThe dot matrix font is only used with Number Perf layouts. To create

Strany 221

286 ConCADBarcode Element TabBarcode elements are available for both laser and inkjet templates. Barcode elements for inkjet templates have more colo

Strany 222 - 210 Export Setups

Maxsys and MX Series Software Administrator’s Guide 287 2D Barcode ElementThe 2 dimensional bar code element is available only for an inkjet template.

Strany 223 - Chapter 16: Keyboard Entry

iii Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:1. R

Strany 224 - Using Keyboard Entry

18 About the Software3. In the Available Columns box, select the column(s) to display and click Add > or Add All >>.

Strany 225

288 ConCAD

Strany 226 - 214 Keyboard Entry

Maxsys and MX Series Software Administrator’s Guide 289Appendix F: Ring Search Vision ProfilesThis chapter includes information about the configuratio

Strany 227 - Chapter 17: Back Up and

290There are two algorithms for searching for reference marks in the laser module:• ConCADThis algorithm is suitable only for reference marks consist

Strany 228 - Create the Backup

Maxsys and MX Series Software Administrator’s Guide 291 3. Click to select the Vision Profiles tab. 4. At the bottom of the tab, click Add Vision Mark

Strany 229 - Restoring the System

2928. In the black box is an image display area that will be used to show the camera's view of the product. This image is the basis for determin

Strany 230 - 218 Back Up and Restore

Maxsys and MX Series Software Administrator’s Guide 293 The dialog box shows capture pro

Strany 231 - Appendix A: Miscellaneous

294Defining and Testing Search ParametersOnce the image is loaded, the search parameters can be defined and tested to see how well they perform.The i

Strany 232 - Audit Settings

Maxsys and MX Series Software Administrator’s Guide 295 The blue rectangle shows the sea

Strany 233 - Microsoft Windows Updates

296 The blue X marks the target position chosen by the search algorithm. The green X mar

Strany 234 - System Default User Name

Maxsys and MX Series Software Administrator’s Guide 297 Determining the Minimum ScoreThe Minimum Score is used to enable the detection of products ins

Strany 235

Maxsys and MX Series Software Administrator’s Guide 19 If an input file is loaded multiple times,

Strany 236 - Font Mapping Procedure

298To determine an acceptable setting for the minimum score, misoriented products can be examined, or you may shift the ideal location around on the

Strany 237

Maxsys and MX Series Software Administrator’s Guide 299 In the Search Results area, the match point chosen is at (246, 72), and a score of 46.38 is ac

Strany 238

300 Within the search zone, there are still no matches (which is ideal for this misorien

Strany 239 - Verification Module

Maxsys and MX Series Software Administrator’s Guide 301 The max score above was 88.41. S

Strany 240

302The batch of images can now be tested using the defined search parameters. Using the navigation buttons below the captured image, navigate to the

Strany 241 - Quick Stock Capture

Maxsys and MX Series Software Administrator’s Guide 303

Strany 242

304Ring Search ControlsThis section provides descriptions for each of the parameters in the Ring Search dialog.

Strany 243

Maxsys and MX Series Software Administrator’s Guide 305 Navigation Bar (Below Image Area)Allows navigation through the images in the capture directory

Strany 244

306Match Count (Overall): The total number of points matching the search criteria over the entire image. If "Search Entire Image" is unchec

Strany 245

Maxsys and MX Series Software Administrator’s Guide 307 Keep in mind that if the directory access permissions prevent storage of the image, a time hit

Strany 246

20 About the SoftwareGeneral Tab Use the General tab to set the font and font size for the

Strany 247 - Verifying the Correct Stock

308can copy and paste the proper pixel values from this sample image to construct a new image, one pixel or line at a time. This is the Target-T.bmp

Strany 248 - Verifying Card Stock

Maxsys and MX Series Software Administrator’s Guide 309 Search AlgorithmThe search algorithm is as follows:• For each point in the search area, comput

Strany 250

Maxsys and MX Series Software Administrator’s Guide 21 Toolbars Tab Use the toolbar tab to

Strany 251 - Vision Registration

22 About the SoftwareThe font and font size changes apply to the table column headings and table values (1 in the following figure). Tables can be se

Strany 252

Maxsys and MX Series Software Administrator’s Guide 23 Event LogUse the Event Log tools to query and view system events. System events are logged auto

Strany 253 - Font Creation Process

24 About the SoftwareGlobal SetupsGlobal setups are used across multiple applications within the software. For more information, refer to Chapter 10:

Strany 254

Maxsys and MX Series Software Administrator’s Guide 25 and modules in a central issuance system. Trained personnel can access Diagnostics information

Strany 255 - Appendix C: Artista VHD

26 About the SoftwareSoftware InformationError MessagesA list of error messages is available by selecting Help | Error Messages. Error messages are c

Strany 256 - 244 Artista VHD Module

Maxsys and MX Series Software Administrator’s Guide 27Chapter 2: ProductionThis chapter provides procedures for working with jobs in the Production ap

Strany 258 - 246 Artista VHD Module

28 ProductionLoading JobsAfter the Load command is started, the Load dialog box opens. From this dialog box, you can load jobs into the database for

Strany 259

Maxsys and MX Series Software Administrator’s Guide 29 2. Select the job file by clicking Browse, navigating to the file location, and clicking Open.

Strany 260 - 248 Artista VHD Module

30 Production2. From the Syntera menu bar, select Applications | Order Processing | Order Input.3. Click Browse in the toolbar, navigate to the order

Strany 261 - Translation Tool

Maxsys and MX Series Software Administrator’s Guide 31 6. From the Syntera menu bar, select Applications | Production Planning | Basic Job Creation. T

Strany 262

32 Production8. Exit Syntera.9. In Maxsys/MX Series Production, select the All Jobs tab. The job is listed under the Pooled tab.

Strany 263

Maxsys and MX Series Software Administrator’s Guide 33 Loading CardSystem Manager (CSM) JobsPerform one of the following procedures to load CardSystem

Strany 264

34 Production 3. Select the CSM tab at the bottom of the dialog box.4. Click Connect to

Strany 265

Maxsys and MX Series Software Administrator’s Guide 35 Using QuickConnectYou can also use the QuickConnect method for loading CSM jobs.1. Reconfigure

Strany 266

36 Production6. Click Download to load a job file to the directory specified in step 4.The Files field contains a list of previously downloaded files

Strany 267 - Tip Sheet

Maxsys and MX Series Software Administrator’s Guide 37 2. Select the All Jobs tab in the left pane of the screen.Use the Search facility at the bottom

Strany 268

v ContentsChapter 1: About the Software______________________________________________________ 1Introduction __________________________________________

Strany 269 - Appendix E: ConCAD

38 Production12. When the job is complete, click Release on the toolbar.A. (Optional) Click in the bottom of the dialog box and type instructions to

Strany 270 - Layout Properties

Maxsys and MX Series Software Administrator’s Guide 39 Viewing Cards/FormsPerform the following steps to view cards or forms within a job on a Maxsys/

Strany 271 - Guidelines

40 Production2. Open the print preview dialog. • Right-click on the selected records and then click Print Preview.or• Click the Print Preview button.

Strany 272 - Profiles

Maxsys and MX Series Software Administrator’s Guide 41 The following table describes the dialog properties on the Front, Back, and Both Sides tabs.• C

Strany 273 - Laser Profiles

42 ProductionRemaking JobsIf a job requires a remake, perform one of the following procedures.Remaking a Maxsys/MX Series JobUse the following proced

Strany 274 - Compatibility

Maxsys and MX Series Software Administrator’s Guide 43 Stopping/Pausing/Cancelling JobsWhen a job is running, perform the following steps on the Produ

Strany 275

44 Production B. Enter the card/form number that you want to be the first card/form in t

Strany 276

Maxsys and MX Series Software Administrator’s Guide 45 1. In the Production window (Applications | Production), select the Job Details tab.2. On the J

Strany 277

46 Production5. Click OK. The Split Job dialog box opens, confirming at what record index number the job split. The split job appears in the My Work

Strany 278 - The Toolbar

Maxsys and MX Series Software Administrator’s Guide 47 • Input File (not available on Syntera) - Enter the Input File name into the text box. The prog

Strany 279 - Element Tab Definitions

vi Chapter 2: Production_____________________________________________________________ 27Monitoring Production_________________________________________

Strany 280 - Processing Tab

48 ProductionHolding/Removing Products from a Syntera Job1. In the Production window (Applications | Production), select the All Jobs tab.2. Under th

Strany 281 - Bitmap Settings Tab

Maxsys and MX Series Software Administrator’s Guide 49 3. Click Restore Audit on the upper bar to restore an audit file from the database in the event

Strany 282 - BMP Laser Details

50 Production• Click Remove to free the allocated materials.• Click Edit Status to change information about the material. (Enter the required informa

Strany 283

Maxsys and MX Series Software Administrator’s Guide 51 • If you selected Manual Reconciliation Mode, the Set Good and Set None buttons in the Job Deta

Strany 284 - Verification Tab

52 Production6. Click Apply.The date/time the note was created, as well as the user name of the person who entered it, are inserted before the note t

Strany 285 - Filter Tab

Maxsys and MX Series Software Administrator’s Guide 53Chapter 3: The Event LogThis chapter provides information on querying and viewing system events

Strany 286

54 The Event Log3. On the Time Range tab (displayed by default), select the time range for your query.• Select All Events to include all system event

Strany 287

Maxsys and MX Series Software Administrator’s Guide 55 • Select Restrict to user comment

Strany 288 - Bitmap Image Element

56 The Event Log5. On the Column Filters tab, select the Columns of query data to include in the query. The events can be filtered as follows:

Strany 289 - Bitmap Text Element

Maxsys and MX Series Software Administrator’s Guide 57 6. When the time, filters and column parameters have been selected for your query click OK to p

Strany 290

vii Adding Fields _________________________________________________________________ 67Adding Data Fields _____________________________________________

Strany 291 - Wedge Element

58 The Event LogViewing Message DetailsTo view the details of an event message, double-click the event in the list. You can browse through the messag

Strany 292 - Vector Settings Tab

Maxsys and MX Series Software Administrator’s Guide 59 2. From the Sort Order tab, select either Ascending or Descending and then click Apply. The lis

Strany 293 - Vector Rectangle Element

60 The Event Log5. Click Export to File. The file(s) will be exported to the defined location.Purging the Event LogPerform the following procedure to

Strany 294 - Vector Ellipse Element

Maxsys and MX Series Software Administrator’s Guide 61Chapter 4: Job SetupThis chapter provides information on creating and modifying Job Setups.Creat

Strany 295 - Vector Text Element

62 Job SetupThe Settings TabThe Settings tab allows you to select and define settings for the Job Setup.1. Under the Settings tab, use one of the fol

Strany 296 - Vectorized (TTF) Text Element

Maxsys and MX6000 Software Administrator’s Guide 63 8. Select a Smart Card Operation, Lookup Field, and Match Data Field from their respective lists.9

Strany 298 - Barcode Element Tab

Maxsys and MX Series Software Administrator’s Guide 65Chapter 5: Data SetupThis chapter provides information on creating and modifying Data Setups.Cre

Strany 299 - 2D Barcode Element

66 Data Setup4. Click the Save icon on the toolbar to name and save the new Data Setup.Defining Data Input FilesThe system must be told how to interp

Strany 300 - 288 ConCAD

Maxsys and MX Series Software Administrator’s Guide 67 3. If you selected the Card and Form product type in step 2, define the form information.Before

Strany 301 - Vision Profiles

viii Printing Card Setups_________________________________________________________ 128Chapter 7: Form Setup _________________________________________

Strany 302 - to apply to the laser data

68 Data Setup• FIR fields - File Identification Records (FIR) identify the start of a new logical file in the data stream and provide job processing

Strany 303

Maxsys and MX Series Software Administrator’s Guide 69 3. Double-click on the new field name and then change the name if needed. Do not use spaces in

Strany 304 - Loading Images

70 Data SetupPosition. In the Record Position text box, type a number indicating the exact position of the start of the data for this field.9. Specif

Strany 305

Maxsys and MX Series Software Administrator’s Guide 71 1. Create a new, or double-click an existing Data Setup to open it, and then select the Constan

Strany 306

72 Data Setup1. Create a new, or double-click an existing Data Setup to open it and then select the FIR Fields tab.2. Click New. The new field is add

Strany 307

Maxsys and MX Series Software Administrator’s Guide 73 1. Create a new Data Setup, or double-click an existing Data Setup to open it, and then select

Strany 308 - Setting Light Intensity

74 Data Setup5. Select a Composite Field Result Property from the list and then specify the parameters for the newly-created field as described in th

Strany 309 - Determining the Minimum Score

Maxsys and MX Series Software Administrator’s Guide 75 First Index AfterReturns a numeric value of the character following the first occurrence of a s

Strany 310

76 Data Setup6. Click the Save icon in the toolbar to save the Data Setup.Adding Display FieldsDisplay fields are up to five data fields (data fields

Strany 311

Maxsys and MX Series Software Administrator’s Guide 77 Perform the following procedure to define and order Display fields.1. Create a new Data Setup o

Strany 312

ix Adding a Crypto Device_________________________________________________ 186Deleting Crypto Devices _______________________________________________

Strany 313

78 Data SetupChanging the Order of Data FieldsIt may be necessary to change the order of data fields if the fields in the Data Setup were set up in t

Strany 314

Maxsys and MX Series Software Administrator’s Guide 79Chapter 6: Card SetupThis chapter provides information on creating and modifying Card Setups.A C

Strany 315

80 Card SetupCreating a New Card SetupIf you are creating a Card Setup that is similar to an existing Card Setup, it is often faster and easier to sa

Strany 316 - Ring Search Controls

Maxsys and MX Series Software Administrator’s Guide 81 3. Add elements to the Front (top view) or Back (bottom view) of the virtual card. Drag an elem

Strany 317

82 Card Setup• Define the properties as required, based on the element type. (For more information, refer to "Defining Element Properties"

Strany 318 - Image Capture

Maxsys and MX Series Software Administrator’s Guide 83 Defining Card PropertiesThe Card Properties view allows you to define the properties for the ca

Strany 319 - Ring Search Target Design

84 Card Setup 2. Enter a unique name for the card in the Name text box.3. (Optional) Ent

Strany 320

Maxsys and MX Series Software Administrator’s Guide 85 7. Click Manage Element Groups to add or delete Element Groups. Element Groups allow you to spl

Strany 321 - Search Algorithm

86 Card SetupFor example, if you defined a field PS_Name in your Data Setup, you could define selection criteria that choose your Card Setup based on

Strany 322

Maxsys and MX Series Software Administrator’s Guide 87 2. Click New, then enter up to 9 tab positions using either value in inches or click the icon t

Komentáře k této Příručce